交换机

T75系列管理型二层工业以太网交换机

128 Gbps max. switching capacity and 95.23 Mpps max. switching fabricDesigned to operate in harsh environments of -40°C to 75°CFlexible modular configuration, 3 Module-dedicated slotsSwappable modules for flexibility to work in all kinds of scenariosUp to 24x PoE ports, max. power budget 720 W4x 10 GbE /1 GbE uplink SFP slots4 kinds of power input available for different harsh environmentsITU-T G.8032 ERPS Ring, RSTP, or MRP (Manager/Client) redundancyEN50155 / EN50121-4 certified for railway applicationsPrecision time synchronization with IEEE1588v2 P2P/E2E TC, delay within 50nsCompliant with IEC 62443-4-1 and IEC 62443-4-2 security standardsFlexible and powerful Gateway’s high-density T7528 layer2-managed rackmount switch provides the flexibility to meet all kinds of requirements. Customization is made easy with 8 different switch cores, differing in power supply and uplink ports, and 3 swappable modules of different port types. Of these, PoE ports allow both power and data transmission to wherever the Ethernet cable can reach. With 3 modules of 8 ports each, T7528 supports up to 24 Gigabit PoE/PoE+ (IEEE 802.3af/at) ports, so has at maximum 720W total power budget. Rugged and resilient Designed to work in all kinds of harsh environments, T7528 is EN 60950-1:2006 certified, available in 4 types of power input, fanless, and provides EMC level-3 protection. Reliable operation is guaranteed in the wide-range temperature of -40°C to +75°C. Various supported ring protocols enable self-healing ability for your network. ITU-T G.8032 ERPS Ring can even recover the network within 25 ms on full load of 250 devices. User-friendly WUI allows simple setup of basic functions like VLAN, QoS, IGMP, as well as network diagnostics via Port Mirroring. Proven quality The T7528 Series is compliant with IEC 62443-4-1 and IEC 62443-4-2 standards, which means that its development process as well as product features achieve world-class industrial network security. In addition, ACL by IP/MAC and 802.1x port access control with RADIUS filters unauthorized hosts, helping to keep your network safe. Furthermore, the T7528 Series is EN 50155-certified to ensure reliable performance under a wide range of power supply conditions, and complies with essential sections of EN 50121-4 for railway ground equipment. Consult T7528 datasheet to learn more about modules and configuration examples.

T96系列网管型三层工业以太网交换机

Supports HSR (IEC 62439-3 Clause 5) and PRP (IEC 62439-3 Clause 4)IEC 61850-3 and IEEE 1613 certificationDesigned in compliance with IEC61850-90-4Integrated IEEE 1588v2 hardware-based BC and TC (-BC/SB version)Maximum 128Gbps switching capacity, 95.24Mpps throughputRugged industrial design for harsh environments between -40~85°CFlexible modular configuration; 3 Module-dedicated slotsUp to 24 Gigabit ports, and 4x10 Gigabit SFP Uplink slots, 1PPS BNCITU-T G.8032 ERPS Ring, RSTP, or MRP (Manager/ Client) redundancyAdvanced management features such as QoS and VLANFlexibility: Gateway’s high-density T9628 Rack-mounted managed switch provides the flexibility needed for your application demands. You can choose from among six different Core versions: based on power supply, uplink port configurations and embedded Hardware-Assisted Boundary Clock feature. And you can choose from six different 4- or 8-Port modules to customize your device in a very simple way. Designed for Substations: Layer-3 routing support BGPv4, IPv4 static routing, RIP v1/v2 and OSPFv2. Award-winning Performance: T9628’s IEEE1588v2 Hardware-PTP version received recognition for nanosecond-level accuracy. This makes T9628 one of the most reliable GMC backups. And being embedded with Synchronous Ethernet and with full support for PTP profiles. High-availability, versatility and power: When equipped with High-Availability HSR/PRP modules, T9628 complies with the most stringent redundancy requirements, ensuring no packet loss and guaranteeing GOOSE packets arrive at their respective destinations. T9628‘s high performance provides a network redundant self-recovery mechanism of under 20ms on full load. This enables you to build a reliable network through almost any redundant ring topology. T9628 supports ITU-T G.8032 ERPS Ring, IEEE802.1D-2004 RSTP, STP, MSTP, MRP (Manager/ Client), iA-Ring, iA-Chain and many other compatible ring protocols for network redundancy. With a Multifunctional web dashboard, its offers intelligent features such as Quality of service (QoS), IGMP, port mirroring, and security. It is available in two power input variants: one for low-DC voltage (redundant 24~120VDC input) and one for the more popular High-Voltage applications in the distribution grid (redundant 110~240VAC, 24~120VDC or 120~380VDC input). Additional 4 x 10 Gigabit uplink SFP slots allow T9628 to be the backbone of the substation. Consult T9628 datasheet to learn more about application and configuration mode.

T75系列管理型三层工业以太网交换机

最大128Gbps交换容量,95.24Mpps吞吐量灵活模块化配置,3个专用模块插槽最多24个PoE端口,最大PoE供电预算720W4个1千兆或4个10千兆SFP上行链路插槽支持RIPv1/v2、OSPFv2、IPv4静态路由及组播IP路由ITU-T G.8032 ERPS环网、RSTP、MRP(客户端)以及VRRP冗余功能可选专用MACsec模块,实现超低时延、高吞吐的强安全性能高级管理特性4种电源输入版本,多达20种配置方案适用于-40~75°C恶劣环境的坚固工业设计PROFINET v2.33 CC-B兼容性通过EN50155与EN50121-4铁路及轨旁应用认证灵活:巨微's高密度T7628托管式机架安装交换机将为您提供应用所需的灵活性。您可在8种不同的三层路由核心版本(基于电源与上行链路端口配置)以及5种不同的4/8端口模块中自由选择,并以极为简便的方式定制您的设备。专为PoE设计,宽温适用:T7628支持在任意8端口或4端口组合下提供多达24个千兆端口。特别针对以太网供电需求而设计,24个端口最高可输出720W的以太网供电功率(PoE/PoE+配置——符合802.3af/at标准)。提供3种电源输入版本,通过EN 60950-1:2006认证,专为应对最严苛环境而打造。无风扇设计与EMC Level 3防护确保其在-40至+75°C温度范围内稳定运行,24个PoE端口满载工作,使其几乎适用于各类应用场景。强大且多功能:T7628支持IPv4静态路由、RIPv1/v2、OSPFv2、IGMP、IGMP侦听、PIM密集模式与稀疏模式、DVMRP以及用于路由冗余的VRRP。同时,它还集成了T7528的所有功能(二层版本),并通过ERPS技术实现全负载条件下20毫秒内的网络自愈能力。几乎任何冗余环网拓扑均受支持,包括ITU-T G.8032 RPS环网、IEEE802.1D-2004 RSTP、STP、MSTP、MRP(客户端)、iA-Ring、iA-Chain等众多兼容环网。此外,还可扩展更多附加功能。自动化与物联网就绪:符合Profinet CC-B v2.33标准,使T7628成为您工业自动化网络的理想骨干。T7628系列全面通过EN50155认证,确保在多种电源条件下(如电压波动、断电及电源切换)的可靠性能,并满足EN50121-4地面设备相关关键条款要求。安全:首款工业级托管式安全交换机!通过802.1AE MACsec保护您的局域网免遭窃听与入侵。无额外延迟,保障100%千兆吞吐,专用模块可为您提供极致的内部安全解决方案。.

S53系列

The S53 series is a series of 10 Gigabit Layer 3 industrial switches, all equipped with four 10 Gigabit SFP+ optical ports, boasting advanced hardware processing capabilities and the richest service features. Supporting IPv4/IPv6 hardware dual-stack and line-speed forwarding, it can easily handle the upcoming IPv6 era, providing high-capacity switching capabilities. The S53 series industrial switches have an operating temperature range of -40℃ to 80℃, exhibiting exceptional robustness to withstand various harsh environments. Its DIN rail mounting capability and wide operating temperature range make the S53 series industrial switches a plug-and-play industrial-grade device, providing users with a reliable and convenient solution for Ethernet device networking.Supports port-based user IP+MAC address authentication and port-based 802.1X authentication.Supports Layer 3 and 4 ACL functions for effective defense against ARP attacks and viruses.Supports unique ARP intrusion detection functionality to effectively prevent hackers or attackers from launching increasingly prevalent ARP spoofing attacks via ARP packets.Supports IP Source Guard features to prevent illegal address spoofing, including MAC spoofing, IP spoofing, and MAC/IP spoofing, as well as DoS attacks caused by large-volume address spoofing.Supports multiple spanning tree protocols such as STP, RSTP, and MSTP.Supports the industrial-grade Ethernet ring network protocol ERPS.Supports SNMP V1/V2/V3 network management for device configuration and management;Supports command-line configuration (CLI), and management via Telnet and Console port;Supports encryption methods such as SSH2.0 for enhanced management security;Supports the LLDP protocol for simplified network management;Supports NTP clock protocol and PTP (1588v2) for automatic network time synchronization;Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: DC Input 12-52V DC input 36-72V or AC110-240V Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS53-4G4TFS53-24G8C4TFS53-24G8C4TF.S53-48G4TFPorts4 Gigabit Ethernet ports24 Gigabit Ethernet ports 8 Combo ports24 Gigabit Ethernet ports 8 Combo ports.48 Gigabit Ethernet ports4*10G SFP+ optical ports4*10G SFP+ optical ports.4*10G SFP+ optical ports4*10G SFP+ optical ports.Switching Capacity598Gbps598Gbps.598Gbps598Gbps.Switching forwarding rate222Mpps222Mpps.252Mpps252Mpps.Packet buffer16M16M.16M16M.MAC Address32K32K.32K32K.Whole machine power consumption<20W<30W<30W.<30WSize175.6*135*45.5mm442*325*44mm442*325*44mm.442*325*44mm

S35系列L2管理型交换机

The S35 series is a full gigabit Layer 2 managed industrial switch. It supports 4/8/16/28 gigabit Ethernet ports and 2-16 gigabit fiber ports; supports the Ethernet Layer 2 protocol required by the industrial site to ensure the stability of the communication network; this series of switches adopts low power consumption and fan less design to ensure no Noise interference, while supporting -40~80℃ working temperature and good EMC electromagnetic compatibility performance, ensuring stable work in harsh industrial environments, and building a fast and stable network for industrial applications such as factory automation, intelligent transportation, video surveillance, etc. The terminal access network provides a safe and reliable solution. Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: DC Input 48-57V DC input 36-72V or AC110-220V Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Network protocol: IEEE802.3; 10BASE-T. IEEE802.3i; 10Base-T; IEEE802.3u.100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X;.IEEE802.3x; IEEE802.af; IEEE802.at; IEEE 802.1D-2004 for Spanning Tree Protocol; IEEE 802.1w for Rapid Spanning Tree Protocol; IEEE 802.1s for Multiple Spanning Tree Protocol; IEEE 802.1Q for VLAN Tagging; IEEE 802.1p for Class of Service; IEEE 802.1X for Authentication; IEEE 802.3ad for Port Trunk with LACP; IEEE 802.3az for Energy Efficient Ethernet Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS35-4G2FS35-8G2FS35-8G4FS35-8G8FS35-16G2FS35-16G4FS35-16G8FS35-24G2FS35-24G4FS35-28G4CFS35-12G16F4CFPorts4 Gigabit Ethernet ports8 Gigabit Ethernet ports8 Gigabit Ethernet ports.8 Gigabit Ethernet ports16 Gigabit Ethernet ports16 Gigabit Ethernet ports.16 Gigabit Ethernet ports24 Gigabit Ethernet ports24 Gigabit Ethernet ports.28 Gigabit Ethernet ports12 Gigabit Ethernet ports2 Gigabit SFP optical ports2 Gigabit SFP optical ports.4 Gigabit SFP optical ports8 Gigabit SFP optical ports2 Gigabit SFP optical ports4 Gigabit SFP optical ports2 Gigabit SFP optical ports2 Gigabit SFP optical ports.4 Gigabit SFP optical ports4 Gigabit combo ports16Gigabit SFP optical ports 4 Gigabit combo portsSwitching Capacity128Gbps128Gbps.336Gbps336Gbps.336Gbps336Gbps.128Gbps128Gbps.336Gbps336Gbps.336GbpsSwitching forwarding rate102Mpps102Mpps.126Mpps126Mpps.126Mpps126Mpps.102Mpps102Mpps.126Mpps126Mpps.126MppsPacket buffer4.1M4.1M.4.1M4.1M.4.1M4.1M.4.1M4.1M.4.1M4.1M.4.1MMAC Address8K8K.8K8K.8K8K.16K16K.16K16K.16KWhole machine power consumption<10W<10W.<15W<15W.<15W<15W.<10W<10W.<20W<20W.<20WSize144*105*48mm196*135*54mm145*125*48mm176*135*46mm176*135*46mm.166*137*69mm166*137*69mm.166*137*80mm166*137*80mm.442*325*44mm442*325*44mm.

S17-XG

The S17-XG unmanaged gigabit switch series offers four port options, ranging from five 10/100/1000BASE-T(X) ports to 24 ports. Featuring a modern, slim, and flat design that minimizes footprint, the S17-XG series is ideal for demanding industrial applications, providing superior network performance for those requiring compact solutions. This series supports a wide operating temperature range of -40°C to 75°C, has an IP40 protection rating, and meets 61000-6-4 requirements, ensuring stable operation in various environments and providing a reliable and convenient solution for networking Ethernet devices. Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: DC INPUT: 12-52V Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Network protocol: IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; IEEE802.3u;100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x; Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS17-5GS17-8GS17-16GS17-24GPorts5 gigabit Ethernet ports8 gigabit Ethernet ports16 gigabit Ethernet ports24 gigabit Ethernet portsSwitching Capacity10Gbps16Gbps32Gbps48GbpsSwitching forwarding rate7.44Mpps11.9Mpps23.8Mpps35.7MppsPacket buffer1.2M2M8MMAC Address2K8KWhole machine power consumption<3W<10W<15W<15WSize118(L)*86(W)*39(H)mm143(L)*101(W)*44(H)mm176(L)*134(W)*46(H)mm170(L)*134(W)*46(H)mm

S17-XFXGP

S17-XFXGP series are 1000M unmanaged industrial Ethernet switches. Support 1/2/4/8/16/24 1000M electrical ports (Support POE/POE+), support 1-2 Gigabit optical ports (SFP). support the Industrial Ethernet protocol can ensure the stability of the communication network; Adopts low power consumption, No fan design. Operating temperature of -40°C to 75°C, with super robustness, can adapt to various harsh environments, conveniently placed in a compact control box. The installation characteristics of the guide rail, wide temperature operation, IP40 protection and LED indicator, make it a plug-and-play industrial-grade equipment, providing a reliable and convenient solution for users' Ethernet equipment networking. Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: DC Input 48-57V Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Network protocol: IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; IEEE802.3u;100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x; Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS17-1F1GPS17-1F2GPS17-1F4GPS17-2F4GPS17-2F8GPS17-2F16GPS17-2F8G16GPPorts1 gigabit Ethernet ports (POE/POE+)2 gigabit Ethernet ports(POE/POE+)4 gigabit Ethernet ports(POE/POE+)4 gigabit Ethernet ports(POE/POE+).8 gigabit Ethernet ports(POE/POE+)16 gigabit Ethernet ports(POE/POE+)16 gigabit Ethernet ports(POE/POE+) and 8 gigabit Ethernet portsPorts1 Gigabit SFP optical port1 Gigabit SFP optical port.1 Gigabit SFP optical port2 Gigabit SFP optical port2 Gigabit SFP optical port.2 Gigabit SFP optical port2 Gigabit SFP optical port.Switching Capacity14Gbps14Gbps.14Gbps14Gbps.20Gbps56Gbps56Gbps.Switching forwarding rate3Mpps4.5Mpps7.44Mpps8.9Mpps14.9Mpps26.8Mpps38.7MppsPacket buffer1.2M1.2M.1.2M1.2M.2M4M4M.MAC Address2K2K.2K2K.8K8K.8KWhole machine power consumption<3W<3W.<3W<5W<8W<10W<15WSize118(L)*86(W)*39(H)mm118(L)*86(W)*39(H)mm.143(L)*101(W)*48(H)mm145(L)*105(W)*48(H)mm145(L)*105(W)*48(H)mm.175(L)*137(W)*46(H)mm166(L)*137(W)*88(H)mm

S17-2FXG

The S17-2FXG unmanaged gigabit switch series offers four port options, ranging from two gigabit SFP ports and four 10/100/1000BASE-T(X) auto-sensing Ethernet ports to two gigabit SFP ports and twenty-four 10/100/1000BASE-T(X) auto-sensing Ethernet ports. Featuring a modern, slim, and flat design that minimizes footprint, the S17-2FXG series is ideal for demanding industrial applications, providing superior network performance for those requiring compact solutions. This series supports a wide operating temperature range of -40°C to 75°C, IP40 protection rating, and complies with 61000-6-4 requirements, ensuring stable operation in various environments and providing a reliable and convenient solution for networking Ethernet devices. Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Network protocol: IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; IEEE802.3u;100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x; Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS17-2F4GS17-2F8GS17-2F16GS17-2F24GPorts4 gigabit Ethernet ports8 gigabit Ethernet ports16 gigabit Ethernet ports24 gigabit Ethernet portsPorts2 Gigabit SFP optical port2 Gigabit SFP optical port.2 Gigabit SFP optical port2 Gigabit SFP optical port.Switching Capacity14Gbps20Gbps56Gbps56Gbps.Switching forwarding rate8.9Mpps14.9Mpps26.8Mpps38.7MppsPower characteristicsDC INPUT: 12-52VDC INPUT: 12-52V.DC INPUT: 12-52VAC INPUT: 110-264VPacket buffer1.2M2M4MMAC Address2K8KWhole machine power consumption<5W<8W<10W<15WSize145(L)*105(W)*48(H)mm145(L)*105(W)*48(H)mm.175(L)*137(W)*46(H)mm440(L)*200(W)*44(H)mm

S17-1FXG

The S17-1FXG XG unmanaged gigabit switch series offers four port options, ranging from one gigabit SFP port and one 10/100/1000BASE-T(X) auto-sensing Ethernet port to one gigabit SFP port and eight 10/100/1000BASE-T(X) auto-sensing Ethernet ports. Featuring a modern, slim, and flat design that minimizes footprint, the S17-1FXG series is ideal for demanding industrial applications, providing superior network performance for those requiring compact solutions. This series supports a wide operating temperature range of -40°C to 75°C, IP40 protection rating, and complies with 61000-6-4 requirements, ensuring stable operation in various environments and providing a reliable and convenient solution for networking Ethernet devices. Operating temperature: -40~85°C Storage temperature: -40~85°C Relative humidity: 5%~95% No condensation Power characteristics: DC INPUT: 12-52V Support dual power supply redundancy Support built-in overcurrent 4.0A protection Support reverse connection protection Network protocol: IEEE802.3 10BASE-T; IEEE802.3i 10Base-T; IEEE802.3u;100Base-TX/FX; IEEE802.3ab 1000Base-T; IEEE802.3z 1000Base-X; IEEE802.3x; Industry Standard: EMI :FCC Part 15 Subpart B Class A,EN 55022 Class A EMS :IEC(EN)61000-4-2(ESD) : ±8kV contact discharge,±15kV air discharge IEC(EN)61000-4-3(RS) : 10V/m(80~1000MHz) IEC(EN)61000-4-4(EFT) : power cable:±4kV;data cable : ±2kV IEC(EN)61000-4-5(Surge) : /Ethernet ports: ±4kV CM//±2kV DM IEC(EN)61000-4-6(Radio frequency conduction) : 3V(10kHz~150kHz),10V(150kHz~80MHz) IEC(EN)61000-4-16(Common mode conduction) : 30V cont. 300V,1s IEC(EN )61000-4-8 Shock :IEC 60068-2-27 Freefall :IEC 60068-2-32 Vibration:IEC 60068-2-6 Mechanical properties Housing: metal Installation: DIN rail type, wall-mounted installation Cooling method: natural cooling, no fan LED indicator Power indicator: PWR Interface indicator lights: Electrical port (Link/ACT) Protection level IP40 Mean time between failures 300,000 HoursProduct ModelS17-1F1GS17-1F2GS17-1F4GS17-1F8GPorts1 gigabit Ethernet ports2 gigabit Ethernet ports4 gigabit Ethernet ports8 gigabit Ethernet portsPorts1 Gigabit SFP optical port1 Gigabit SFP optical port.1 Gigabit SFP optical port1 Gigabit SFP optical port.Switching Capacity14Gbps14Gbps.14Gbps20GbpsSwitching forwarding rate3Mpps4.5Mpps7.44Mpps13.4MppsPacket buffer1.2M1.2M.1.2M2MMAC Address2K2K.2K8KWhole machine power consumption<3W<3W.<3W<5WSize118(L)*86(W)*39(H)mm118(L)*86(W)*39(H)mm.143(L)*101(W)*48(H)mm143(L)*101(W)*48(H)mm.